Research over the past 25 years and the use of accelerator mass spectrometry (AMS) have demonstrated benefits of single‐atom counting of 14C compared with scintillation monitoring of 14C radioactive decay for a multitude of applications in drug development studies. These include pharmacokinetics and metabolism studies, microdosing studies, and quantification of DNA adducts. In the last decade, the possibility of single‐atom counting using lasers has been demonstrated, providing the possibility of simplified laboratory‐based systems, which can equal or excel AMS sensitivity and provide scintillation system convenience without high levels of radioactivity. To achieve the required sensitivity, optical storage cavities have been used to enhance the laser interaction of the low densities of radiocarbon present. Two types of laser technologies have been used‐cavity ring‐down spectroscopy (CRDS) and intracavity opto‐galvanic spectroscopy (ICOGS). Problems to be overcome to achieve routine use have included separation of the 14C signal from backgrounds, achievement of acceptable precision and accuracy, reduction of measurement times for small samples, and improvement in the ease of use for the operator. Both technologies have achieved impressive results to date using samples of order 1 mg with CRDS and 10 μg with ICOGS. Commercial development is the next step. 相似文献
Doxorubicin (DOX) is the most commonly used anticancer drug; however, it has limited use because prolonged administration may result in severe cardiotoxicity. Simvastatin (SIM), generally prescribed for hypercholesterolaemia, has also shown salubrious results in the monotherapy or combinational drug therapy of different cancers in various models. Nanoparticle drug delivery systems are a novel way of improving therapeutics and also improving the absorption and specificity of drugs towards tumour cells. In this study, we exploited this technology to increase drug specificity and minimize imminent adverse effects. In this study, the antitumour activity of the combination formulas of DOX and SIM, either loaded in water (DOX‐SIM‐Solution) or nanoemulsions (NEs) (DOX‐SIM‐NE), was evaluated in a Swiss albino mouse model of Ehrlich ascites carcinoma. The anticancer effect was assessed by quantifying the change in body weight, mean survival time, and percent increase in lifespan (%ILS), determining haematological and serum biochemical parameters (liver function test, kidney function test and lipid profile parameters) as well as studying the histopathological alterations in liver tissues. We observed a clear increase in %ILS of the DOX‐SIM‐Solution group (265.30) that was double the %ILS of the DOX‐SIM‐NE group (134.70). However, DOX‐SIM‐NE had a non‐toxic effect on the haematological parameters, whereas DOX‐SIM‐Solution increased the levels of haemoglobin and lymphocytes. Furthermore, the encapsulation of SIM and DOX into NEs improved the levels of all serum biochemical parameters compared to the DOX‐SIM‐Solution. A reduction in the side effects of DOX‐SIM‐NE on the liver was also established using light microscopy, which revealed that the morphologies of the hepatocytes of the mice were less affected by administration of the DOX‐SIM‐NE treatment than with the DOX‐SIM‐Solution treatment. The study showed that incorporating SIM into the DOX‐loaded‐NE formulation remarkably improved its efficiency and simultaneously reduced its adverse effects. 相似文献
Silent sinus syndrome (SSS) is a rare disorder involving bony remodeling of the maxillary sinuses, including collapse of the orbital floor. It is typically unilateral and seen in the setting of chronic maxillary sinusitis. Patients present with enophthalmos and hypoglobus occasionally accompanied by diplopia. The condition is generally diagnosed with CT imaging and treated surgically. While SSS is most often reported as very slowly progressive, we report a patient with evidence of significant remodeling of the maxillary sinus over a period of 5.5 months. 相似文献
Purpose: To study, with computational models, the utility of power modulation to reduce tissue temperature heterogeneity for variable nanoparticle distributions in magnetic nanoparticle hyperthermia.
Methods: Tumour and surrounding tissue were modeled by elliptical two- and three-dimensional computational phantoms having six different nanoparticle distributions. Nanoparticles were modeled as point heat sources having amplitude-dependent loss power. The total number of nanoparticles was fixed, and their spatial distribution and heat output were varied. Heat transfer was computed by solving the Pennes’ bioheat equation using finite element methods (FEM) with temperature-dependent blood perfusion. Local temperature was regulated using a proportional-integral-derivative (PID) controller. Tissue temperature, thermal dose and tissue damage were calculated. The required minimum thermal dose delivered to the tumor was kept constant, and heating power was adjusted for comparison of both the heating methods.
Results: Modulated power heating produced lower and more homogeneous temperature distributions than did constant power heating for all studied nanoparticle distributions. For a concentrated nanoparticle distribution, located off-center within the tumor, the maximum temperatures inside the tumor were 16% lower for modulated power heating when compared to constant power heating. This resulted in less damage to surrounding normal tissue. Modulated power heating reached target thermal doses up to nine-fold more rapidly when compared to constant power heating.
Conclusions: Controlling the temperature at the tumor-healthy tissue boundary by modulating the heating power of magnetic nanoparticles demonstrably compensates for a variable nanoparticle distribution to deliver effective treatment. 相似文献
AbstractObjectives: This study examined word use as an indicator of interpersonal positive reframing in daily conversations of couples coping with breast cancer and as a predictor of stress.Design: The Electronically Activated Recorder (EAR) and Linguistic Inquiry and Word Count (LIWC) were used to examine naturally occurring word use conceptually linked to positive reframing (positive emotion, negative emotion, and cognitive processing words).Sample: Fifty-two couples coping with breast cancer.Methods: Couples wore the EAR, a device participants wear, that audio-recorded over one weekend (>16,000 sound files), and completed self-reports of positive reframing (COPE) and stress (Perceived Stress Scale). LIWC, a software program, measured word use.Findings: Both partners’ word use (i.e., positive emotion and cognitive processing words) was associated with their own reported positive reframing, and spouses’ word use was also indicative of patients’ positive reframing. Results also revealed that, in general, words indicating positive reframing predicted lower levels of stress.Conclusions: Findings supported the hypothesis that partners—and particularly spouses of breast cancer patients—may assist each other’s coping by positively reframing the cancer experience and other negative experiences in conversation. 相似文献
A hydrogel rectal spacer (HRS) is a medical device that is approved by the U.S. Food and Drug Administration to increase the separation between the prostate and rectum. We conducted a cost-effectiveness analysis of HRS use for reduction in radiation therapy (RT) toxicities in patients with prostate cancer (PC) undergoing external beam RT (EBRT).
Methods and Materials
A multistate Markov model was constructed from the U.S. payer perspective to examine the cost-effectiveness of HRS in men with localized PC receiving EBRT (EBRT alone vs EBRT + HRS). The subgroups analyzed included site of HRS placement (hospital outpatient, physician office, ambulatory surgery center) and proportion of patients with good baseline erectile function (EF). Data on EF, gastrointestinal and genitourinary toxicities incidence, and potential risks associated with HRS implantation were obtained from a recently published randomized clinical trial. Health utilities and costs were derived from the literature and the 2018 Physician Fee Schedule and were discounted 3% annually. Quality-adjusted life years (QALYs) and costs were modeled for a 5-year period from receipt of RT. Probabilistic sensitivity analysis and value-based threshold analyses were conducted.
Results
The per-patient 5-year incremental cost for spacers administered in a hospital outpatient setting was $3578, and the incremental effectiveness was 0.0371 QALYs. The incremental cost-effectiveness ratio was $96,440/QALY for patients with PC undergoing HRS insertion in a hospital and $39,286/QALY for patients undergoing HRS insertion in an ambulatory facility. For men with good baseline EF, the incremental cost-effectiveness ratio was $35,548/QALY and $9627/QALY in hospital outpatient and ambulatory facility settings, respectively.
Conclusions
Based on the current Medicare Physician Fee Schedule, HRS is cost-effective at a willingness to pay threshold of $100,000. These results contain substantial uncertainty, suggesting more evidence is needed to refine future decision-making. 相似文献